Evaluation of an FIA Operated Amperometric Bacterial Biosensor, Based on Pseudomonas Putida F1 for the Detection of Benzene, Toluene, Ethylbenzene, and Xylenes (BTEX)

dc.contributor.authorRasinger, Josef D.
dc.contributor.authorMarrazza, Giovanna
dc.contributor.authorBriganti, Fabrizio
dc.contributor.authorScozzafava, Andrea
dc.contributor.authorMascini, Marco
dc.contributor.authorTurner, Anthony P. F.
dc.date.accessioned2009-06-04T18:55:33Z
dc.date.available2009-06-04T18:55:33Z
dc.date.issued2005
dc.description.abstractRecently, the development and optimization of a flow injection analysis (FIA) operated bacterial biosensor based on the aerobic catabolism of Pseudomonas putida ML2 was reported in the literature (Lanyon et al. 2004, 2005). By adapting information from these reports, we investigated whether operating parameters and procedures of the benzene biosensor could be directly applied to a new system based on a different bacterial strain for the detection of the whole benzene, toluene, ethylbenzene, and xylenes range. Cells of the investigated bacterial strain, Pseudomonas putida F1, were immobilized between two cellulose acetate membranes and fixed onto a Clark dissolved oxygen electrode. The P. putida F1 aerobically degrades benzene, toluene, and ethylbenzene (BTE) (Cho et al. 2000). The BTE biosensor in kinetic mode FIA displayed a linear range of 0.02-0.14 mM benzene (response time: 5 min, base-line recovery time: 15 min), 0.05-0.2 mM toluene (response time: 8 min, baseline recovery time: 20 min), and 0.1-0.2 mM ethylbenzene (response time: 12 min, baseline recovery time: 30 min), respectively. Due to the differences in sensitivity, response, and baseline recovery times for BTE, it was possible to differentiate each compound in mixtures of these volatile organic compounds (VOCs). No response for xylenes could be obtained since they cannot be completely metabolized by this bacterial strain. However, it was reported that the range of compounds degradable by P. putida F1 can possibly be expanded by cultivating the cells on different carbon sources (Choi et al. 2003). The sensor showed good intra- and interassay reproducibility, and all obtained results were comparable with those reported in the literature. The demonstrated reproducibility and the simplicity and ease of use as well as the portability for in situ measurements indicates that the biosensor could be suitable as a reliable initial warning device for elevated BTE levels in indoor and outdoor environments.en_UK
dc.identifier.citationJosef D. Rasinger; Giovanna Marrazza; Fabrizio Briganti; Andrea Scozzafava; Marco Mascini; A. P. F. Turner Evaluation of an FIA Operated Amperometric Bacterial Biosensor, Based on Pseudomonas Putida F1 for the Detection of Benzene, Toluene, Ethylbenzene, and Xylenes (BTEX), Analytical Letters, Vol 38, Iss 10 pages 1531-1547en_UK
dc.identifier.issn1532-236X
dc.identifier.urihttp://dx.doi.org/10.1081/AL-200065793
dc.identifier.urihttp://hdl.handle.net/1826/3414
dc.language.isoenen_UK
dc.publisherTaylor and Francisen_UK
dc.subjectFlow injection analysisen_UK
dc.subjectbenzeneen_UK
dc.subjecttolueneen_UK
dc.subjectethylbenzeneen_UK
dc.subjectxylenesen_UK
dc.subjectvolatile organic compoundsen_UK
dc.titleEvaluation of an FIA Operated Amperometric Bacterial Biosensor, Based on Pseudomonas Putida F1 for the Detection of Benzene, Toluene, Ethylbenzene, and Xylenes (BTEX)en_UK
dc.typePostprinten_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation of a FIA operated-Turner-2005.pdf
Size:
76.28 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.89 KB
Format:
Item-specific license agreed upon to submission
Description: