Labeless AC impedimetric antibody-based sensors with pg ml-1 sensitivities for point-of-care biomedical applications.
dc.contributor.author | Barton, Andrew C. | - |
dc.contributor.author | Collyer, Stuart D. | - |
dc.contributor.author | Davis, Frank | - |
dc.contributor.author | Garifallou, Goulielmos-Zois | - |
dc.contributor.author | Tsekenis, Georgios | - |
dc.contributor.author | Tully, Elizabeth | - |
dc.contributor.author | O'Kennedy, Richard | - |
dc.contributor.author | Gibson, Tim | - |
dc.contributor.author | Millner, Paul A. | - |
dc.contributor.author | Higson, Seamus P. J. | - |
dc.date.accessioned | 2011-10-11T07:32:55Z | |
dc.date.available | 2011-10-11T07:32:55Z | |
dc.date.issued | 2009-01-01T00:00:00Z | - |
dc.description.abstract | This paper describes the development and characterisation of labeless immunosensors for (a) the cardiac drug digoxin and (b) bovine serum albumin (BSA). Commercial screen-printed carbon electrodes were used as the basis for the sensors. Two methods were used to immobilise antibodies at the electrode surface. Aniline was electropolymerised onto these electrodes to form a thin planar film of conductive polyaniline; the polyaniline film was then utilised as a substrate to immobilise biotinylated anti-digoxin using a classical avidin- biotin affinity approach. As an alternative approach, poly(1,2-diaminobenzene) was electrodeposited onto the carbon electrodes and this modified surface was then sonochemically ablated to form an array of micropores. A second electropolymerisation step was then used to co-deposit conductive polyaniline along with antibodies for BSA within these pores to produce a microarray of polyaniline protrusions with diameters of several μm, containing entrapped anti- BSA | en_UK |
dc.identifier.citation | Andrew C. Barton, Stuart D. Collyer, Frank Davis, Goulielmos-Zois Garifallou, Georgios Tsekenis, Elizabeth Tully, Richard O'Kennedy, Tim Gibson, Paul A. Millner, Seamus P.J. Higson, Labeless AC impedimetric antibody-based sensors with pg ml-1 sensitivities for point-of-care biomedical applications, Biosensors and Bioelectronics, Volume 24, Issue 5, Selected Papers from the Tenth World Congress on Biosensors Shangai, China, May 14-16, 2008, 1 January 2009, Pages 1090-1095 | - |
dc.identifier.issn | 0956-5663 | - |
dc.identifier.uri | http://dx.doi.org/10.1016/j.bios.2008.06.001 | - |
dc.identifier.uri | http://dspace.lib.cranfield.ac.uk/handle/1826/3196 | |
dc.language.iso | en_UK | - |
dc.publisher | Elsevier Science B.V., Amsterdam. | en_UK |
dc.subject | AC impedance | en_UK |
dc.subject | Immunosensor | en_UK |
dc.subject | Polyaniline | en_UK |
dc.subject | Microelectrode | en_UK |
dc.subject | BSA | en_UK |
dc.subject | Digoxin | en_UK |
dc.title | Labeless AC impedimetric antibody-based sensors with pg ml-1 sensitivities for point-of-care biomedical applications. | en_UK |
dc.type | Article | - |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Labeless AC impedimetric antibody-based sensors with pg ml-1 sensitivities for point-of-care biomedical applications-2009.pdf
- Size:
- 398.34 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1