Multivariate analysis methods for veterinary diagnostics using SIFT-MS

dc.contributor.advisorBessant, Conrad
dc.contributor.authorSpooner, Andrew
dc.date.accessioned2011-07-15T15:52:25Z
dc.date.available2011-07-15T15:52:25Z
dc.date.issued2010
dc.description.abstractSelected ion flow tube mass spectroscopy (SIFT-MS) is an analytical method for the investigation of volatile organic compounds (VOCs). It produces mass to charge (m/z) ratio ion counts with a range of 10-200 m/z. Current data analysis involves sifting through the spectra files one at a time looking for peaks of interest. This is time consuming and requires expert knowledge. This thesis proposes, implements and demonstrates a novel approach to the analysis of SIFT-MS data using multivariate techniques similar to those employed to analyse electronic nose and gas chromatography mass spectroscopy (GCMS) data. The methodology was developed using a set of samples created in the laboratory that belonged to two groups which contained different VOCs found in biological samples. The methodology requires the removal of the m/z peaks associated with the precursors, then principal component analysis (PCA) and partial least squares discriminant analysis (PLSDA) methods were evaluated for biomarker discovery and sample classification. Both methods produced excellent results, identifying the volatiles in the mixtures and being able to classify samples with 100% accuracy. This methodology was then tested using a variety of samples. Ammonia was found as a possible marker for bovine TB (Mycobacterium bovis) infection using serum samples taken from wild badgers. Discrimination results of an accuracy of 67%±6% were acquired. The number of sample needed to build the best performing model from this dataset was empirically shown to be 120. It was shown to be effective for the discrimination of serum samples from cattle taken before and after introduction of bovine TB (Mycobacterium bovis) bacteria in a clinical trial (accuracy of 85% achieved). A similar dataset pertaining to infection by Mannheimia haemolytica failed to produce models that performed as well as the others - this is suspect to be due to a poor experimental design. Finally, discrimination accuracies of 88% for urine samples collected from cattle from herds infected with Mycobacterium paratuberculosis and 90% for urine samples collected in the same bovine TB trial as above were achieved. The novel multivariate approach to SIFT-MS data analysis has been shown to be effective with a number of datasets but it is sensitive to the experimental design. Recommendation for the consideration required for analysis using this method have been made.en_UK
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/5702
dc.language.isoenen_UK
dc.publisherCranfield Universityen_UK
dc.rights© Cranfield University 2010. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright owner.en_UK
dc.titleMultivariate analysis methods for veterinary diagnostics using SIFT-MSen_UK
dc.typeThesis or dissertationen_UK
dc.type.qualificationlevelDoctoralen_UK
dc.type.qualificationnamePhDen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Andrew_Spooner_Thesis_2010.pdf
Size:
6.44 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission
Description: