Development of on-line FTIR spectroscopy for siloxane detection in biogas to enhance carbon contactor management

Date

2015-04-04

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Department

Type

Article

ISSN

0039-9140

item.page.extent-format

Citation

Hepburn CA, Vale P, Brown AS, et al., (2015) Development of on-line FTIR spectroscopy for siloxane detection in biogas to enhance carbon contactor managemen. Talanta, Volume 141, August 2015, pp. 128-136

Abstract

Activated carbon filters are used to limit engine damage by siloxanes when biogas is utilised to provide electricity. However, carbon filter siloxane removal performance is poorly understood as until recently, it had not been possible to measure siloxanes on-line. In this study, on-line Fourier Transform Infrared (FTIR) spectroscopy was developed to measure siloxane concentration in real biogas both upstream (86.1–157.5 mg m−3) and downstream (2.2–4.3 mg m−3) of activated carbon filters. The FTIR provided reasonable precision upstream of the carbon vessel with a root mean square error of 10% using partial least squares analysis. However, positive interference from volatile organic carbons was observed in downstream gas measurements limiting precision at the outlet to an RMSE of 1.5 mg m−3 (47.8%). Importantly, a limit of detection of 3.2 mg m−3 was identified which is below the recommended siloxane limit and evidences the applicability of on-line FTIR for this application.

Description

item.page.description-software

item.page.type-software-language

item.page.identifier-giturl

Keywords

Adsorption, Biogas, CHP, Landfill, Interference, VOCs

Rights

Attribution 3.0 Unported