Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor

dc.contributor.authorSwedrowski, Leon
dc.contributor.authorCiszewski, Tomasz
dc.contributor.authorGelman, Leonid
dc.date.accessioned2016-08-23T14:07:21Z
dc.date.available2016-08-23T14:07:21Z
dc.date.issued2016-07-01
dc.description.abstractDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides an overview of selected methods of diagnosis of induction motor bearings, based on measurement of the supply current. The problem here is the high disturbance components level of the motor current in relation to diagnostic components. The paper presents the new approach to signal analysis solutions, based on statistical methods, which have been adapted to be used by this diagnostic system. First experimental results with use of this method are also presented, they confirm the advantages of this method.en_UK
dc.identifier.citationSwedrowski, L., Ciszewski, T., Gelman, L. (2016) Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor, 19th World Conference on Non-Destructive Testing, Munich, German, 13-17 Juneen_UK
dc.identifier.urihttp://www.ndt.net/search/docs.php3?showForm=off&id=19787
dc.identifier.urihttps://dspace.lib.cranfield.ac.uk/handle/1826/10395
dc.language.isoenen_UK
dc.publisherNDT.neten_UK
dc.rightsAttribution-NoDerivatives 4.0 Internationalen_UK
dc.rights.urihttps://creativecommons.org/licenses/by-nd/4.0/
dc.titleCurrent based Normalized Triple Covariance as a bearings diagnostic feature in induction motoren_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Current_based_Normalized_Triple_Covariance_as_a_bearings_diagnostic_feature_in_induction_motor_2016.pdf
Size:
541.83 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission
Description: