'Optimisation of an in-process lineal dielectric sensor for liquid moulding of carbon fibre composites'
Date published
Free to read from
Supervisor/s
Journal Title
Journal ISSN
Volume Title
Publisher
Department
Type
ISSN
Format
Citation
Abstract
Data: -RTM experiment - 4 bar clamping pressure.xlsx Excel spreadsheet containing the impedance/admittance signals and corresponding covered length for the the PI-LD lineal sensor alongside the visual flow front measurements using video for the 4 bar clamping pressure RTM trial -RTM experiment - 7 bar clamping pressure.xlsx Excel spreadsheet containing the impedance/admittance signals and corresponding covered length for the PI-LD and NyPU lineal sensor, the impedance signals for the PI-LD cure sensor, and the temperature evolution used for the kinetics/specific heat capacity evolution for the 6 bar clamping pressure RTM trial -Air sensor tests.xlsx Excel spreadsheet containing the impedance and admittance spectra of 3 PU sensors in air Models: -FLEXPDE sensor in air.dat FLEXPDE script for 2D FE complex electric field model of sensor in air -FLEXPDE sensor in resin.dat FLEXPDE script for 2D FE complex electric field model of sensor in resin Images: - Flow front mm_process time min.zip Compressed set of images used to identify the flow front position in the 4 bar clamping pressure RTM trial. Files are named to indicate the flow front position and process time. For example, file 150-1.70 is the image corresponding to a flow position of 150 mm at 1.70 min.