Apparent Reduction in the Value of the d 33 Piezoelectric Coefficient in PZT Thick Films.

dc.contributor.authorDorey, Robert A.-
dc.contributor.authorWhatmore, Roger W.-
dc.date.accessioned2011-06-21T23:02:05Z
dc.date.available2011-06-21T23:02:05Z
dc.date.issued2002-01-01T00:00:00Z-
dc.description.abstractThick PZT films (1 - 20 m) have been prepared using a composite sol gel technique whereby PZT powder and a PZT producing sol are formed into a slurry and spin coated onto silicon wafers. The maximum relative permittivity obtained was approximately 80% of that exhibited by bulk PZT of comparable composition. However, the d 33, f and e 31, f [1] piezoelectric coefficients were shown to be significantly lower than that of bulk PZT. It has been proposed that the measured value of d 33, f is affected appreciably by particle-particle rotation and substrate clamping leading to reduced poling efficiency which may also greatly reduce the value of e 31, f observed. Samples with high levels of porosity have been shown to exhibit a reduced value of d 33 . This was attributed to 31 and 51 mode piezoelectrically generated charges caused by the bending and shearing of particle-particle bridges. The effect of substrate clamping, on d 33, f and poling, has been studied by monitoring the changes in position and intensity of the (200)/(002) X-ray diffraction (XRD) peaks of composite films. The presence of the substrate was found to introduce tensile stresses parallel to the film plane which distorted the unit cell. Subsequent permanent polarisation following poling was found to be reduced due to the presence of these stresses. The discrepancies between the values of d 33 measured on thick films and bulk ceramics were highlighted as being of particular importance if thick film materials are to be modelled for device applications. Thick film piezoelectric coefficients (i.e. those of the combined film-substrate structure) should not be used in place of material piezoelectric coefficients when attempting to model the behaviour of devices. Such actions would inevitably lead to erroneous results.en_UK
dc.identifier.citationR. A. Dorey; R. W. Whatmore. Apparent Reduction in the Value of the d 33 Piezoelectric Coefficient in PZT Thick Films. Integrated Ferroelectrics, Volume 50, Issue 1 2002 , pages 111-119en_UK
dc.identifier.issn1058-4587-
dc.identifier.urihttp://dx.doi.org/10.1080/10584580215518-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/2324
dc.language.isoen_UKen_UK
dc.publisherTaylor & Francisen_UK
dc.subjectLead Zirconate Titanateen_UK
dc.subjectPzten_UK
dc.subjectPiezoelectricen_UK
dc.subjectD33en_UK
dc.subjectE31en_UK
dc.subjectPolingen_UK
dc.subjectFilmsen_UK
dc.titleApparent Reduction in the Value of the d 33 Piezoelectric Coefficient in PZT Thick Films.en_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Apparent reduction in d33-2002.pdf
Size:
318.06 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
42 B
Format:
Plain Text
Description: