Response of a coriolis gas flow meter to steady and transient wet gas flow conditions

dc.contributor.authorSalehi, Seyed Milad
dc.contributor.authorLao, Liyun
dc.contributor.authorSimms, Nigel
dc.contributor.authorDrahm, Wolfgang
dc.contributor.authorLin, Yaoying
dc.contributor.authorRieder, Alfred
dc.contributor.authorGüttler, Andreas
dc.date.accessioned2024-05-20T12:50:58Z
dc.date.available2024-05-20T12:50:58Z
dc.date.issued2024-04-13
dc.description.abstractCoriolis devices are continuously evolving to meet the demands of different conditions, such as wet gas flow. However, their application in wet gas flow has not yet been thoroughly explored. The impact of steady flow disturbances on Coriolis flow meters is well-documented, and empirical compensation or correction methods can be implemented accordingly. However, there has been inadequate investigation into the response of Coriolis meters under transient flow conditions and their comparison with steady flow in a wet gas. In this study, a Coriolis device was horizontally installed in a 50 mm pipe diameter. The experimental fluids consisted of air and water, with Lockhart-Martinelli (XLM) values ranging from 0.02 to 0.40. Steady and transient flow conditions at different gas and liquid flow rates were studied. The findings demonstrate the capability of standard deviation (STD) in distinguishing transient flow from steady one. Additionally, a strong correlation was observed between XLM and gas Over-Reading (OR) across various gas flow rates and XLM values. This correlation is particularly evident for XLM < 0.1. At extremely low liquid loading (XLM < 0.05), the average percentage error remains below 7 % even without the utilization of any correction models. Furthermore, the impact of different sensor installations, which had been largely overlooked in previous studies, was investigated.en_UK
dc.identifier.citationSalchi SM, Lao L, Simms N, et al., (2024) Response of a coriolis gas flow meter to steady and transient wet gas flow conditions. In: Proceedings of the 9th World Congress on Momentum, Heat and Mass Transfer, 11-13 April 2024, London, United Kingdom, Article number ICMFHT 140en_UK
dc.identifier.isbn978-1-990800-34-4
dc.identifier.issn2371-5316
dc.identifier.urihttp://doi.org/10.11159/icmfht24.140
dc.identifier.urihttps://dspace.lib.cranfield.ac.uk/handle/1826/21639
dc.language.isoen_UKen_UK
dc.publisherAvestia Publishingen_UK
dc.rightsAttribution 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectCoriolis flow meteren_UK
dc.subjectStandard Deviationen_UK
dc.subjectSensor Orientationen_UK
dc.subjectTwo-phase flowen_UK
dc.subjectWet gasen_UK
dc.titleResponse of a coriolis gas flow meter to steady and transient wet gas flow conditionsen_UK
dc.typeConference paperen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Coriolis_gas_flow_meter-2024.pdf
Size:
829.08 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: