New reactive polymer for protein immobilisation on sensor surfaces

dc.contributor.authorKyprianou, Dimitris-
dc.contributor.authorGuerreiro, Antonio R.-
dc.contributor.authorChianella, Iva-
dc.contributor.authorPiletska, Elena V.-
dc.contributor.authorFowler, Steven A.-
dc.contributor.authorKarim, Kal-
dc.contributor.authorWhitcombe, Michael J.-
dc.contributor.authorTurner, Anthony P. F.-
dc.contributor.authorPiletsky, Sergey A.-
dc.date.accessioned2012-02-01T23:03:08Z
dc.date.available2012-02-01T23:03:08Z
dc.date.issued2009-01-01T00:00:00Z-
dc.description.abstractImmobilisation of biorecognition elements on transducer surfaces is a key step in the development of biosensors. The immobilisation needs to be fast, cheap and most importantly should not affect the biorecognition activity of the immobilised receptor. A novel protocol for the covalent immobilisation of biomolecules containing primary amines using an inexpensive and simple polymer is presented. This tri-dimensional (3D) network leads to a random immobilisation of antibodies on the polymer and ensures the availability of a high percentage of antibody binding sites. The reactivity of the polymer is based on the reaction between primary amines and thioacetal groups included in the polymer network. These functional groups (thioacetal) do not need any further activation in order to react with proteins, making it attractive for sensor fabrication. The novel polymer also contains thiol derivative groups (disulphide groups or thioethers) that promote self-assembling on a metal transducer surface. For demonstration purposes the polymer was immobilised on Au Biacore chips. The resulting polymer layer was characterised using contact angle meter, atomic force microscopy (AFM) and ellipsometry. A general protocol suitable for the immobilisation of bovine serum albumin (BSA), enzymes and antibodies such as polyclonal anti-microcystin-LR antibody and monoclonal anti-prostate specific antigen (anti-PSA) antibody was then optimised. The affinity characteristics of developed immunosensors were investigated in reaction with microcystin-LR, and PSA. The calculated detection limit for analytes depended on the properties of antibodies. The detection limit for microcystin-LR was 10 ng mL−1 and for PSA 0.01 ng mL−1. The non-specific binding of analytes to synthesised polymers was very low. The polymer-coated chips were stored for up to 2 months without any noticeable deterioration in their ability to react with proteins. These findings make this new polymer very promising for the development of low-cost, easy to prepare and sensitive biosensen_UK
dc.identifier.citationKyprianou D, Guerreiro AR, Chianella I, et al., (2009) New reactive polymer for protein immobilisation on sensor surfaces, Biosensors and Bioelectronics, Volume 24, Issue 5, Selected Papers from the Tenth World Congress on Biosensors Shangai, China, May 14-16, 2008, 1 January 2009, Pages 1365-1371-
dc.identifier.issn0956-5663-
dc.identifier.urihttp://dx.doi.org/10.1016/j.bios.2008.07.070-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/6923
dc.language.isoen_UK-
dc.publisherElsevier Science B.V., Amsterdam.en_UK
dc.subjectSPRen_UK
dc.subjectThiol compoundsen_UK
dc.subjectPolymeren_UK
dc.subjectProtein immobilisationen_UK
dc.subjectPSAen_UK
dc.subjectMicrocystin-LRen_UK
dc.titleNew reactive polymer for protein immobilisation on sensor surfacesen_UK
dc.typeArticle-

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
New Reactive Polymer for Protein Immobilisation on Sensor Surfaces-2009.pdf
Size:
281.08 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
18 B
Format:
Plain Text
Description: