dc.description.abstractThe mechanisms of skull impact loading may change following surgical interventions such as the removal of bone lesions, but little is known about the consequences in the event of subsequent head trauma. We, therefore, prepared acrylonitrile butadiene styrene human skull models based on clinical computed tomography skull data using a three-dimensional printer. Six replicate physical skull models were tested, three with bone excisions and three without. A drop tower was used to simulate the impact sustained by falling backwards onto the occipital lobe region. The impacts were recorded with a high-speed camera, and the occipital strain response was determined by digital image correlation. Although the hole affected neither the magnitude nor the sequence of the fracture pattern, the digital image correlation analysis highlighted an increase in strain around the excised area (0.45%–16.4% of the principal strain). Our approach provides a novel method that could improve the quality of life for patients on many fronts, including protection against trauma, surgical advice, post-operative care, advice in litigation cases, as well as facilitating general biomechanical research in the area of trauma injuries.en_UK
dc.identifier.citationFranceskides C, Leger T, Horsfall I, et al., (2020) Evaluation of bone excision effects on a human skull model - I: Mechanical testing and digital image correlation. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, Volume 234, Issue 4, April 2020, pp.337-345en_UK
dc.identifier.issn0954-4119
dc.identifier.urihttps://doi.org/10.1177/0954411919891885
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/15531
dc.language.isoenen_UK
dc.publisherSageen_UK
dc.rightsAttribution-NonCommercial 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.subjectBiopsyen_UK
dc.subjectbone fractureen_UK
dc.subjectstrainsen_UK
dc.subjectdigital image correlationen_UK
dc.subjectphysical modelsen_UK
dc.titleEvaluation of bone excision effects on a human skull model - I: Mechanical testing and digital image correlation.en_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation_of_bone_excision_effects_on_a_human_skull_model_I-2020.pdf
Size:
1.88 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: