Characterisation of textile embedded electrodes for use in a neonatal smart mattress electrocardiography system

dc.contributor.authorDore, Henry
dc.contributor.authorAviles-Espinosa, Rodrigo
dc.contributor.authorLuo, Zhenhua
dc.contributor.authorAnton, Oana
dc.contributor.authorRabe, Heike
dc.contributor.authorRendon-Morales, Elizabeth
dc.date.accessioned2021-02-09T12:01:20Z
dc.date.available2021-02-09T12:01:20Z
dc.date.issued2021-02-02
dc.description.abstractHeart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring systemen_UK
dc.identifier.citationDore H, Aviles-Espinosa R, Luo Z, et al., (2021) Characterisation of textile embedded electrodes for use in a neonatal smart mattress electrocardiography system. Sensors, Volume 21, Issue 3, February 2021, Article number 999en_UK
dc.identifier.issn1424-8220
dc.identifier.urihttps://doi.org/10.3390/s21030999
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/16313
dc.language.isoenen_UK
dc.publisherMDPIen_UK
dc.rightsAttribution 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectwearablesen_UK
dc.subjectmedical devicesen_UK
dc.subjectelectric potential sensoren_UK
dc.subjectelectrodeen_UK
dc.subjectelectrocardiogramen_UK
dc.titleCharacterisation of textile embedded electrodes for use in a neonatal smart mattress electrocardiography systemen_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Characterisation_of_textile_embedded_electrode_for_use_in_a_neonatal_smart_mattress-2021.pdf
Size:
3.09 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: