Methane-specific gas detectors: the effect of natural gas composition

dc.contributor.authorHodgkinson, Jane-
dc.contributor.authorPride, Russ D.-
dc.date.accessioned2012-12-10T23:02:06Z
dc.date.available2012-12-10T23:02:06Z
dc.date.issued2010-10-31T00:00:00Z-
dc.description.abstractCertain gas sensors, particularly those based on optical spectroscopy, have enabled the detection of individual gas species such as methane with low cross-sensitivity to other gases. For gas-specific instruments used to measure natural gas leaks, this paper considers whether it is necessary to consider the other components of natural gas in addition to methane. We have quantified the effect of gas compositional variation on methane-based measurements on the ppm, %LEL and %volume scales. %LEL measurements, important for safety applications, are the most challenging for methane-specific detection. Acceptable levels of error have been drawn from gas detector standards and by comparison with established gas detectors. The fundamental error expected from a methane-specific detector, as a result of variations in gas composition, would be larger than this benchmark on the %LEL scale. However for gas-specific detection, measurement of an additional component such as ethane is shown to reduce the error to below the benchmark level. This has been demonstrated experimentally using an instrument based on tunable diode laser spectroscopy.en_UK
dc.identifier.citationJ. Hodgkinson and R.D. Pride, Methane-specific gas detectors: the effect of natural gas composition, Measurement Science and Technology, Volume 21, Number 10, Paper Number 105103.
dc.identifier.issn0957-0233-
dc.identifier.urihttp://dx.doi.org/10.1088/0957-0233/21/10/105103-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/4785
dc.language.isoen_UK-
dc.publisherIop Publishing Ltden_UK
dc.rightsThis is an author-created, un-copyedited version of an article accepted for publication in [insert name of journal]. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at 10.1088/0957-0233/21/10/105103
dc.subjectlower explosive limit lower flammable limit natural gas gas detection spectroscopy standards spectroscopyen_UK
dc.titleMethane-specific gas detectors: the effect of natural gas compositionen_UK
dc.typeArticle-

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Methane-specific_gas_detectors_2010.pdf
Size:
828.46 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
18 B
Format:
Plain Text
Description: