Comparative ambient and indoor particulate matter analysis of operation theatres of government and private (trust) hospitals of Lahore, Pakistan

dc.contributor.authorNimra, A.
dc.contributor.authorAli, Z.
dc.contributor.authorKhan, M. N.
dc.contributor.authorGulshan, T.
dc.contributor.authorSidra, S.
dc.contributor.authorGardezi, J. R.
dc.contributor.authorTarar, M. R.
dc.contributor.authorSaleem, M.
dc.contributor.authorNasir, Zaheer A.
dc.contributor.authorColbeck, Ian
dc.date.accessioned2019-05-15T14:48:12Z
dc.date.available2019-05-15T14:48:12Z
dc.date.issued2015-06-30
dc.description.abstractThe link between infection and indoor air quality (IAQ) in operating theatres is well established. The level of airborne particulate matter (PM) in operating theatres in Pakistan has not yet been studied comprehensively. Monitoring of both indoor (operating theatre) and outdoor concentrations of PM in both activity and non-activity time periods was done using a DUSTTRAK Aerosol Monitor (TSI Model 8520) and DRX Aerosol Monitor (TSI Model 8533) for 24 hours. Two hospitals in Lahore were selected: Services Hospital (government – site 1) and Shalamar Hospital (private – site 2). The highest concentration of PM was observed in the orthopaedic operating theatre at site 1 during working hours with an average concentration of 757(±540), 809(±58), 824(±585), 875(±586) and 970(±581) µg/m³ of PM1 ,PM2.5, PM4, PM10and PMTotalrespectively while the average PM2.5outdoor concentration was 294 µg/m3 . The minimum average PM concentration was found in the orthopaedic operating theatre at site 2 during working hours: 18(±8), 19(±8), 20(±9), 26(±9) and 39(±9) µg/m³ for PM1, PM2.5, PM4, PM10 and PMTotal respectively. The use of vertical laminar air flow ventilation strategy was found to be an effective measure in reducing PM levels and it might be possible to predict the air quality of operating theatres by determining PM dust load. Factors such as ventilation system, door opening /closing rates, building age, possible sources of infiltration, number of people present in the operating area all play a role in influencing PM concentrations in operating theatres.en_UK
dc.identifier.citationNimra A, Ali Z, Khan MN, et al., Comparative ambient and indoor particulate matter analysis of operation theatres of government and private (trust) hospitals of Lahore, Pakistan. The Journal of Animal and Plant Sciences, Volume 25, Issue 3, 2015, pp. 628-635en_UK
dc.identifier.issn1018-7081
dc.identifier.urihttp://www.thejaps.org.pk/docs/Supplementary/v-25-sup-2/53.pdf
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/14168
dc.language.isoenen_UK
dc.publisherPakistan Agricultural Scientists Forumen_UK
dc.subjectParticulate matteren_UK
dc.subjectOperation theatre environmenten_UK
dc.subjectIAQ in hospitalsen_UK
dc.subjectPakistanen_UK
dc.titleComparative ambient and indoor particulate matter analysis of operation theatres of government and private (trust) hospitals of Lahore, Pakistanen_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
particulate_matter_analysis_of_operation_theatres-Lahore-2015.pdf
Size:
402.21 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: