Effectiveness of grease interceptors in food service establishments for controlling fat, oil and grease deposition in the sewer system

Date published

2023-12-20

Free to read from

Supervisor/s

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Department

Type

Article

ISSN

0048-9697

Format

Citation

Sultana N, Roddick F, Jefferson B, et al., (2023) Effectiveness of grease interceptors in food service establishments for controlling fat, oil and grease deposition in the sewer system. Science of the Total Environment, Volume 912, February 2024, Article number 169441

Abstract

The water industry worldwide experiences numerous sewer blockages each year, partially attributed to the accumulation of fat, oil and grease (FOG). Managing this issue involves various strategies, including the requirement for installation of grease interceptors (GIs) installation. However, the claimed efficacy of commercial GIs of eliminating 99 % of FOG has been questioned for many years because FOG deposit formation occurs despite food service establishments (FSEs) using GIs, therefore detailed understanding of FOG wastewater compositions and its removal by GIs is required. This study provides an insight into the key FOG components such as FOG particle size, metals and fatty acid (FA) profile in GI influent and effluent, and within the GI, at three different FSEs. Analysis of FAs identified substantial proportions of extra-long-chain FAs in the effluents, including arachidic (C20:0), behenic (C22:0), mead (C20:3), lignoceric (C24:0), and nervonic (C24:1) acids. In contrast, the household kitchen released palmitic (C16:0), oleic (C18:1) and linoleic (C18:2) acids. It was further observed that scums effectively remove the larger FOG particles, leaving only 10 % below 75.4 μm. Notably, FSEs which employed automatic dishwashers produced up to 80.4 % of particles ≤45 μm, whereas FSEs and household kitchen which used handwash sinks generated only 36.9 % and 26.3 % of particles ≤45 μm, respectively. This study demonstrated that the commercial GIs do not remove FOG entirely but clearly demonstrated that they discharge high concentrations of FOG with extra-long FFAs which were attributed to the occurrence of microbial activity and hydrolysis of triglycerides within the GI, potentially contributing to FOG deposition.

Description

Software Description

Software Language

Github

Keywords

Fat, Oil and grease, Grease interceptor, Food service establishments, Fatty acids, And particle sizes

DOI

Rights

Attribution 4.0 International

Relationships

Relationships

Resources

Funder/s