Water exclusion from tunnel cavities in the saturated capillary fringe

dc.contributor.authorYoungs, E. G.en_UK
dc.contributor.authorKacimov, A. R.en_UK
dc.contributor.authorObnosov, Yu. V.en_UK
dc.date.accessioned2005-11-23T13:03:32Z
dc.date.available2005-11-23T13:03:32Z
dc.date.issued2004-03en_UK
dc.description.abstractThe problem of water flow around a tunnel cavity located in the saturated capillary fringe on top of a very permeable, freely-draining substratum is considered for the critical non-leakage condition when there is uniform vertical downward flow through the upper surface of the saturated region. In this critical condition the soil-water pressure is equal to zero everywhere on the cavity wall that is also a streamline. The conditions at the upper fringe boundary are that the soil-water pressure is equal to the air-entry value of the soil and the flux through this surface is the uniform infiltration rate. The cavity surface and the fringe boundary which is elevated above the cavity position, are found through conformal mapping and the use of integral representations of nonstandard mixed boundary-value problems. They are calculated for a range of infiltration rates and compared with those obtained by assuming the upper fringe boundary to be horizontal. The exact analysis given here gives larger tunnel cavities than those given by the approximate treatment of the problem. The results have application in the design of underground repositories against entry of seepage water, the construction of protective capillary barriers and in the design of interceptor drainage systems.en_UK
dc.format.extent1946 bytes
dc.format.extent116876 bytes
dc.format.extent126047 bytes
dc.format.mimetypetext/plain
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.identifier.citationE. G. Youngs , A. R. Kacimov and Yu. V. Obnosov, Water exclusion from tunnel cavities in the saturated capillary fringe, Advances in Water Resources, Volume 27, Issue 3, March 2004, Pages 237-243en_UK
dc.identifier.issn0309-1708
dc.identifier.urihttp://hdl.handle.net/1826/908
dc.identifier.urihttp://dx.doi.org/10.1016/j.advwatres.2004.01.004
dc.language.isoenen_UK
dc.publisherElsevier Scienceen_UK
dc.subject.otherMixed boundary value problemsen_UK
dc.titleWater exclusion from tunnel cavities in the saturated capillary fringeen_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Water_exclusion_from_tunnel_cavities-2004.pdf
Size:
231.98 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.9 KB
Format:
Plain Text
Description: