Finite element analysis of SS316L-based five-hole plate implant for fibula reconstruction

dc.contributor.authorQosim, Nanang
dc.contributor.authorEmzain, Zakki Fuadi
dc.contributor.authorMufarrih, AM.
dc.contributor.authorMonasari, Ratna
dc.contributor.authorKusumattaqiin, Fataa
dc.contributor.authorSantoso, Rangga E.
dc.date.accessioned2022-09-20T10:57:50Z
dc.date.available2022-09-20T10:57:50Z
dc.date.issued2022-08-15
dc.description.abstractThis study analyzed the design performance of SS316L-based plate implant for fibula restoration using a Finite Element Analysis approach. The simulated model design has dimensions of 35 x 5 x 1.5 mm and five holes with 2-3 configuration. The results of the bending test simulation showed that the values for both displacement and Von Mises stress that occurred (0.008 mm and 116 MPa of each) were still considerably below the yield stress of the SS316L material. The same results were also shown in the tensile test simulation, although the clamping setting on the plate was changed on the other side. From this finite element analysis approach, the SS316L-based five-hole plate implant design has a fairly good strength performance as a fibular bone-implant restoration product.en_UK
dc.identifier.citationQosim N, Emzain ZF, Mufarrih AM, et al., (2022) Finite element analysis of SS316L-based five-hole plate implant for fibula reconstruction. Journal of Applied Engineering and Technological Science (JAETS), Volume 4, Issue 1, August 2022, pp. 16-23en_UK
dc.identifier.issn2715-6087
dc.identifier.urihttps://doi.org/10.37385/jaets.v4i1
dc.identifier.urihttps://dspace.lib.cranfield.ac.uk/handle/1826/18459
dc.language.isoenen_UK
dc.publisherIntellectual Research and Publication Foundation (Yayasan Riset dan Publikasi Intelektual)en_UK
dc.rightsAttribution 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectplateen_UK
dc.subjectimplanten_UK
dc.subjectfinite element methoden_UK
dc.subjectvon misesen_UK
dc.subjectfibulaen_UK
dc.subjectSS316Len_UK
dc.titleFinite element analysis of SS316L-based five-hole plate implant for fibula reconstructionen_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
five-hole_plate_implant_for_fibula_reconstruction-2022.pdf
Size:
710.35 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: