An experimental survey of metal artefact reduction in computed tomography

dc.contributor.authorMouton, Andre-
dc.contributor.authorMegherbi Bouallagui, Najla-
dc.contributor.authorVan Slambrouck, Katrien-
dc.contributor.authorNuyts, Johan-
dc.contributor.authorBreckon, Toby P.-
dc.date.accessioned2014-01-30T17:56:18Z
dc.date.available2014-01-30T17:56:18Z
dc.date.issued2013-11-01T00:00:00Z-
dc.description.abstractWe present a survey of techniques for the reduction of streaking artefacts caused by metallic objects in X-ray Computed Tomography (CT) images. A comprehensive review of the existing state-of- the-art Metal Artefact Reduction (MAR) techniques, drawn almost exclusively from the medical CT literature, is supported by an experimental comparison grounded in an evaluation based on a standard scienti c comparison protocol for MAR methods using a software generated medical phan- tom image. This experimental comparison is further extended by considering novel applications of CT imagery consisting of isolated metal objects with no surrounding tissue, as is encountered in typical engineering and security screening CT applications. We nd that the performance of twelve state-of-the-art MAR techniques to be fairly consistent across the two domains and demonstrate the feasibility of a reference-free quantitative performance measure. The literature review and experi- mentation demonstrate several trends. In particular, the major limitations of state-of-the-art MAR techniques are a dependence on prior knowledge, a sensitivity to input parameters and a shortage of comprehensive performance analyses. This study thus extends previous works by: comparing several state-of-the-art MAR techniques; considering both medical and non-medical applications and performing a comprehensive quantitative analysis, taking into account image quality as well as computational requirements.en_UK
dc.identifier.citationAndre Mouton, Najla Megherbi, Katrien Van Slambrouck, Johan Nuyts, Toby P. Breckon, An experimental survey of metal artefact reduction in computed tomography. Journal of X-Ray Science and Technology, Volume 21, Number 2, 2013, pp. 193-226.
dc.identifier.issn0895-3996-
dc.identifier.urihttp://dx.doi.org/10.3233/XST-130372-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/8204
dc.language.isoen_UK-
dc.publisherElsevier Science B.V., Amsterdamen_UK
dc.titleAn experimental survey of metal artefact reduction in computed tomographyen_UK
dc.typeArticle-

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
An_Experimental_Survey_of_Metal_Artefact_Reduction-2013.pdf
Size:
1.56 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
18 B
Format:
Plain Text
Description: