Optical coherence tomography with a Fizeau interferometer configuration

dc.contributor.authorCasaubieilh, P.-
dc.contributor.authorFord, Helen D.-
dc.contributor.authorJames, Stephen W.-
dc.contributor.authorTatam, Ralph P.-
dc.contributor.editorHeidi, Ottevaere-
dc.contributor.editorPeter, DeWolf-
dc.contributor.editorDiederik, S. Wiersma-
dc.date.accessioned2012-07-20T23:01:15Z
dc.date.available2012-07-20T23:01:15Z
dc.date.issued2005-12-31T00:00:00Z-
dc.description.abstractWe report the investigation of a Fizeau interferometer-based OCT system. A secondary processing interferometer is necessary in this configuration, to compensate the optical path difference formed in the Fizeau interferometer between the end of the fibre and the sample. The Fizeau configuration has the advantage of 'downlead insensitivity', which eliminates polarisation fading. An optical circulator is used in our system to route light efficiently from the source to the sample, and backscattered light from the sample and the fibre end through to the Mach-Zehnder processing interferometer. The choice of a Mach- Zehnder processing interferometer, from which both antiphase outputs are available, facilitates the incorporation of balanced detection, which often results in a large improvement in the Signal-to-Noise ratio (SNR) compared with the use of a single detector. Balanced detection comprises subtraction of the two antiphase interferometer outputs, implying that the signal amplitude is doubled and the noise is well reduced. It has been discerned that the SNR drops when the refractive index variation at a boundary is small. Several OCT images of samples (resin, resin + crystals, fibre composite) are presented.en_UK
dc.identifier.citationP. Casaubieilh, H. D. Ford, S. W. James and R. P. Tatam. Optical coherence tomography with a Fizeau interferometer configuration. Proceedings of the SPIE Nano- and Micro-Metrology, 16-17 June 2005, Munich, Germany. Volume 5858, 58580I. Eds. Heidi Ottevaere, Peter DeWolf, Diederik S. Wiersma
dc.identifier.issn0277-786X-
dc.identifier.urihttp://dx.doi.org/10.1117/12.612737-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/7403
dc.publisherInternational Society for Optical Engineering; 1999en_UK
dc.subjectOptical Coherence Tomography, Fizeau interferometer, optical fibresen_UK
dc.titleOptical coherence tomography with a Fizeau interferometer configurationen_UK
dc.typeConference paper-

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Optical_coherence_tomography-Fizeau-2005.pdf
Size:
151.02 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
18 B
Format:
Plain Text
Description: