An electrochemical sensor based on carboxymethylated dextran modified gold surface for ochratoxin A analysis

dc.contributor.authorHeurich, Meike-
dc.contributor.authorKadir, Mohamad Kamal Abdul-
dc.contributor.authorTothill, Ibtisam E.-
dc.date.accessioned2012-09-11T23:01:21Z
dc.date.available2012-09-11T23:01:21Z
dc.date.issued2011-08-10T00:00:00Z-
dc.description.abstractA disposable electrochemical immunosensor method was developed for ochratoxin A analysis to be applied for wine samples by using a screen-printed gold working electrode with carbon counter and silver/silver chloride pseudo-reference electrode. An indirect competitive enzyme-linked immunosorbent assay (ELISA) format was constructed by immobilising ochratoxin A conjugate using passive adsorption or covalent immobilisation via amine coupling to a carboxymethylated dextran (CMD) hydrogel on the gold working electrode. Electrochemical detection was performed using 3,3′,5,5′-tetramethylbenzidine dihyrochloride (TMB) and hydrogen peroxide with horse radish peroxidase (HRP) as the enzyme label. Chronoamperometry at -150mV vs. onboard screen-printed Ag-AgCl pseudo-reference electrode was then used to detect the generated signal. The performance of the assay and the sensor was optimised and characterised in pure buffer conditions before applying to wine samples. The resulting immunosensor for ochratoxin A in buffer achieved a limit of detection of 0.5μgL-1 with a linear dynamic detection range of 0.1-10μgL-1 for passive adsorption of the toxin conjugate. While for covalent immobilisation through CMD-modified gold electrode, a limit of detection of 0.05μgL-1 was achieved with a linear dynamic detection range of 0.01-100μgL-1. The CMD-modified gold immunosensor was then evaluated in spiked and affinity purified wine samples achieving a detection limit comparable to buffer solutions (0.05μgL-en_UK
dc.identifier.citationMeike Heurich, Mohamad Kamal Abdul Kadir, Ibtisam E. Tothill, An electrochemical sensor based on carboxymethylated dextran modified gold surface for ochratoxin A analysis, Sensors and Actuators B: Chemical, Volume 156, Issue 1, 10 August 2011, Pages 162–168.
dc.identifier.issn0925-4005-
dc.identifier.urihttp://dx.doi.org/10.1016/j.snb.2011.04.007-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/7566
dc.publisherElsevier Science B.V., Amsterdam.en_UK
dc.rightsNOTICE: this is the author’s version of a work that was accepted for publication in Sensors and Actuators B: Chemical. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Sensors and Actuators B: Chemical, VOL 156, ISSUE 1, (2011) DOI:10.1016/j.snb.2011.04.007
dc.titleAn electrochemical sensor based on carboxymethylated dextran modified gold surface for ochratoxin A analysisen_UK
dc.typeArticle-

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
An_electrochemical_sensor-2011.pdf
Size:
577.38 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
18 B
Format:
Plain Text
Description: