Chemical cleaning of potable microfiltration and ultrafiltration membranes

dc.contributor.advisorJudd, Simon J.
dc.contributor.authorPorcelli, Nicandro
dc.date.accessioned2010-11-08T15:16:19Z
dc.date.available2010-11-08T15:16:19Z
dc.date.issued2009-06
dc.description.abstractConcerns over possible waterborne disease forced drinking water supply companies in England and Wales to adopt microfiltration and ultrafiltration technologies rapidly. MF and UF membrane plants are designed to produce water of a consistent quality regardless of throughput and fluctuations in the feedwater quality. To operate well they need to maintain flux and balance the rate of fouling, and chemical cleaning performance is critical to this. Giant steps have been taken into characterizing the foulants scientifically in the last few years while cleaning is reactive and ad hoc. This thesis explores the basis for a corresponding cleaning science for the technology to develop quantitively. Cleaning performance was defined in terms of a response to combinations of explanatory variables in a materials limited cleaning envelope. The study focused on applying variations of cleanant concentration, applied temperature and soak times to a variety of membranes fouled with different waters and regimes. An experimental design was developed and applied consistently to a number of different sampled sites; allowing an optimised recovery from the polynomial expressions for each treatment, through factorial analysis of the data. The size and variety of the data set analysed allowed comparison and quantification of the different deviations from optimal cleaning response. This effect was seen to vary temporally and with operating regime and the methods usefulness as a practical tool in the membrane plant lifecycle was considered. Cost evaluation of the variation in cleaning response showed that sub-optimal cleaning costs and energy use may be significant and the thesis also illustrated how module geometry affects initial cake deposition and thus cleanability. By demonstrating the potential for cleaning factor analysis, the potential for a combined heuristic and predictive cleaning control science is possible, but will need new strategies to manage technology change.
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/4659
dc.language.isoenen_UK
dc.publisherCranfield Universityen_UK
dc.rights© Cranfield University 2009. All rights reserved. No part of this publication may be reproduced without written permission of the copyright owneren_UK
dc.titleChemical cleaning of potable microfiltration and ultrafiltration membranesen_UK
dc.typeThesis or dissertationen_UK
dc.type.qualificationlevelDoctoralen_UK
dc.type.qualificationnameEngDen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nicandro_Porcelli_Thesis_2009.pdf
Size:
7.88 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission
Description: