The development and evaluation of an ultrasonic fatigue unit

dc.contributor.authorClifton, T. E.
dc.date.accessioned2017-06-22T10:18:17Z
dc.date.available2017-06-22T10:18:17Z
dc.date.issued1963-03
dc.description.abstractA fatigue test apparatus operating at 20 kc/s is described. The unit is based on a standard magnetostrictive drive system as used in high energy stresswave generators. An automatic counting device has been developed and incorporated in the final equipment, resulting in improvements in accuracy and reproducibility of results. Some typical results of tests on aluminium alloys are presented.en_UK
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/12093
dc.language.isoenen_UK
dc.publisherCollege of Aeronauticsen_UK
dc.relation.ispartofseriesCoA/N-141en_UK
dc.relation.ispartofseries141en_UK
dc.titleThe development and evaluation of an ultrasonic fatigue uniten_UK
dc.typeReporten_UK