Test report no. PLBO/6: wear tests of PERPRO tools grade CLV, machining meehanite
Date published
1963-12
Free to read from
Supervisor/s
Journal Title
Journal ISSN
Volume Title
Publisher
College of Aeronautics
Department
Type
Report
ISSN
Format
Citation
Abstract
Tools of grade CLV were tested at 300 fpm cutting speed, 0.010
in./rev. feed and 0.10 in. depth of cut to 0.030 in. flankwear. The
results gave a mean tool life of 37 minutes which should be compared with the results given in Report No. PLB0/1 for grades CLV 403, A, B and C.