Test report no. PLBO/6: wear tests of PERPRO tools grade CLV, machining meehanite

Date

1963-12

Supervisor/s

Journal Title

Journal ISSN

Volume Title

Publisher

College of Aeronautics

Department

Type

Report

ISSN

Format

Free to read from

Citation

Abstract

Tools of grade CLV were tested at 300 fpm cutting speed, 0.010

in./rev. feed and 0.10 in. depth of cut to 0.030 in. flankwear. The

results gave a mean tool life of 37 minutes which should be compared with the results given in Report No. PLB0/1 for grades CLV 403, A, B and C.