Coherent fibre bundles in full-field swept-source OCT

dc.contributor.authorFord, Helen D.-
dc.contributor.authorTatam, Ralph P.-
dc.contributor.editorFujimoto, J. G.-
dc.contributor.editorIzatt, J. A.-
dc.contributor.editorTuchin, V. V.-
dc.date.accessioned2011-03-31T23:07:27Z
dc.date.available2011-03-31T23:07:27Z
dc.date.issued2009-02-20T00:00:00Z-
dc.description.abstractEndoscopic OCT probes deliver light to the measurement region via a single optical fibre mounted in a probe head. The output beam is focused onto the sample, providing a single point measurement. The beam is translated, using mechanical scanning at the probe tip, to address a line or area of sampling points and produce an image. We are investigating a swept-source OCT system incorporating coherent fibre bundles, to allow many measurement points to be addressed, within an area of the sample, without the need for mechanical motion within the endoscope probe. Scanning components are still present at the input of our system, but are no longer required within the flexible ndoscope section. This allows a small-diameter, electrically passive probe to be engineered using off-the-shelf scanning components. A common-path probe design is proposed, in which the bundle is external to the OCT interferometer. This eliminates contrast variations caused by non-controllable differences in the state of polarisation between fibres. Imaging bundle fibres are typically few-moded, which can lead to ghost features and reduced SNR in OCT images, but the common-path configuration also removes cross-mode interference problems, and reduces dispersion artefacts. OCT images of a microscope cover-slip and a sample of spring onion, acquired using the swept-source, bundle-based OCT system are presented. Features peculiar to the inclusion of the fibre bundle are discussed, and directions for future development of the system are outlined.en_UK
dc.identifier.citationHelen D. Ford and Ralph P. Tatam. Coherent fibre bundles, imaging bundles, OCT, optical fibre sensing. Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XIII, March 2009, edited by James G. Fujimoto, Joseph A. Izatt, Valery V. Tuchin, Proc. of SPIE Vol. 7168, 71682P
dc.identifier.issn1605-7422-
dc.identifier.urihttp://dx.doi.org/10.1117/12.808953-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/5053
dc.language.isoen_UKen_UK
dc.subjectCoherent fibre bundles, imaging bundles, OCT, optical fibre sensingen_UK
dc.titleCoherent fibre bundles in full-field swept-source OCTen_UK
dc.typeConference paperen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Coherent_fibre_bundles-2009.pdf
Size:
324.89 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
42 B
Format:
Plain Text
Description: