Characterisation of human tissues analogues for ballistic testing
Date published
Free to read from
Supervisor/s
Journal Title
Journal ISSN
Volume Title
Publisher
Department
Type
ISSN
Format
Citation
Abstract
Ballistic testing necessarily employs simulant target materials for ethical and fiscal reasons. Current tissue analogues utilised for ballistic testing / research are, however, typically relatively simplistic – such as ballistics soap or gelatin. Consequently, these materials are seldom representative of complex mammalian constructs. In this paper the authors have drawn together core elements of previously published in-house research with the aim of providing insight into potential approaches to create a composite simulant solution. In particular, tissue analogues covering the epidermal, epithelial, connective, muscular and skeletal components are presented. These results highlight the complementary nature of employing a range of tissue simulant materials and, in parallel, the importance – if ballistic testing data is to be truly representative – of fully understanding the nature of the analogues employed.