Enhanced bandwidth nonlinear resonance electromagnetic human motion energy harvester using magnetic-springs and ferrofluid

dc.contributor.authorLi, Chungfang
dc.contributor.authorWu, Shuai
dc.contributor.authorLuk, Patrick Chi-Kwong
dc.contributor.authorGu, Min
dc.contributor.authorJiao, Zongxia
dc.date.accessioned2019-04-05T14:43:57Z
dc.date.available2019-04-05T14:43:57Z
dc.date.issued2019-02-11
dc.description.abstractAn enhanced bandwidth nonlinear resonant electromagnetic energy harvester has been designed to harness low frequency energy from basic human motion. Some vertical stacked cylindrical permanent magnets (PMs) constitute the inertial mass of the proposed harvester, which is suspended axially by two magnetic-springs and circumferentially by ferrofluid within a carbon fiber tube. In order to widen the frequency band and improve harvesting efficiency, two PMs are respectively fixed on the two end caps of the carbon fiber tube, so as to form two magnetic-springs with variable stiffness by cooperating with the PM stack. The self-assembled ferrofluid around the PM stack acts as its bearing system to minimize any friction during its movement. Copper wire are wrapped outside the tube to form the armature winding. The stiffness characteristic of the magnetic-springs and the optimum equilibrium position and number of windings have been determined by finite element method (FEM) analysis. As a proof of concept, a portable prototype of the proposed energy harvester that weighs 110g and with a volume of only 37.7cm $^3$ is fabricated. A series of experiments are carried out and the results show that the frequency band of the harvester becomes wider as the external vibration intensity increases. In addition, the effectiveness of ferrofluid in reducing friction is demonstrated under walking and running conditions. Without ferrofluid, the maximum average outputs are 10.15 mW and 32.53 mW respectively for walking and running. With ferrofluid, the maximum outputs are 17.72 mW and 54.61 mW, representing an increase of 74.58% and 67.88%, respectively. Furthermore, the prototype exhibits an average power density of 1.45 mW/cm $^3$ during running motions, which compares favorably with existing harvesters used in low power wearable devices.en_UK
dc.identifier.citationLi C, Wu S, PCK Luk, Gu M, Zhao J., Enhanced bandwidth nonlinear resonance electromagnetic human motion energy harvester using magnetic-springs and ferrofluid. IEEE/ASME Transactions on Mechatronics, Volume 24, Issue 2, April 2019, pp. 710-717en_UK
dc.identifier.issn1083-4435
dc.identifier.urihttp://doi.org/10.1109/TMECH.2019.2898405
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/14049
dc.language.isoenen_UK
dc.publisherIEEEen_UK
dc.rightsAttribution-NonCommercial 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.subjectNonlinear resonanceen_UK
dc.subjectvibration energy harvesteren_UK
dc.subjecthuman motionen_UK
dc.subjectmagnetic-springen_UK
dc.subjectferrofluiden_UK
dc.subjectsmart fluiden_UK
dc.titleEnhanced bandwidth nonlinear resonance electromagnetic human motion energy harvester using magnetic-springs and ferrofluiden_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
human_motion_energy_harvester-2019.pdf
Size:
2.05 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: