Optimum three-point linkage set up for improving the quality of soil spectra and the accuracy of soil phosphorus measured using an on-line visible and near infrared sensor.

dc.contributor.authorMouazen, Abdul Mounem-
dc.contributor.authorMaleki, M. R.-
dc.contributor.authorCockx, L.-
dc.contributor.authorvan Meirvenne, M.-
dc.contributor.authorvan Holm, L. H. J.-
dc.contributor.authorMerckx, R.-
dc.contributor.authorDe Baerdemaeker, J.-
dc.contributor.authorRamon, Herman-
dc.date.accessioned2011-05-31T23:08:19Z
dc.date.available2011-05-31T23:08:19Z
dc.date.issued2009-04-01T00:00:00Z-
dc.description.abstractOn-line measurement of soil properties using the visible (Vis) and near infrared (NIR) spectroscopy is sensitive to soil-to-sensor distance (D) and angle (α) variations, which have prevented the successful development of on-line soil sensors so far. This study was undertaken to minimise these variations through optimising the three-point linkage of the tractor to improve the quality of soil spectra and the accuracy of plant available phosphorus (P-avl) measured with an on-line soil sensor. The sensor consisted of a tine, to the back of which an optical probe was attached to acquire soil spectra in diffuse reflectance mode from the bottom of the trench opened by the tine. A mobile, fibre-type, Vis–NIR spectrophotometer (Zeiss Corona 45 visnir fibre, Germany), with a measurement range of 306.5–1710.9 nm was used. Five lengths of the third point link (L) of the tractor of 545, 550, 555, 560 and 565 mm were selected to evaluate the quality of spectra collected on-line at 0.15 m tine depth. The on-line measured spectra were corrected to remove the effect of D and α. The correction was evaluated by estimating the accuracy of predicting P-avl using on-line measured spectra and a previously developed P-avl calibrationen_UK
dc.identifier.citationA.M. Mouazen, M.R. Maleki, L. Cockx, M. Van Meirvenne, L.H.J. Van Holm, R. Merckx, J. De Baerdemaeker, H. Ramon, Optimum three-point linkage set up for improving the quality of soil spectra and the accuracy of soil phosphorus measured using an on-line visible and near infrared sensor, Soil and Tillage Research, Volume 103, Issue 1, April 2009, Pages 144-152en_UK
dc.identifier.issn0167-1987-
dc.identifier.urihttp://dx.doi.org/10.1016/j.still.2008.10.006-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/3425
dc.language.isoen_UKen_UK
dc.publisherElsevier Science B.V., Amsterdam.en_UK
dc.subjectVisibleen_UK
dc.subjectNear infrareden_UK
dc.subjectSpectrophotometeren_UK
dc.subjectOn-lineen_UK
dc.subjectSoil sensoren_UK
dc.titleOptimum three-point linkage set up for improving the quality of soil spectra and the accuracy of soil phosphorus measured using an on-line visible and near infrared sensor.en_UK
dc.typeArticleen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Optimum-three-point-linkage-set-up-for-improving-the-quality-of-soil-spectra-2009.pdf
Size:
429.61 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
42 B
Format:
Plain Text
Description: