Estimating measurement uncertainty in the medical laboratory

dc.contributor.advisorNewman, Jeffrey D.
dc.contributor.advisorGomes, Maria Adelina
dc.contributor.authorPlacido, Rui
dc.date.accessioned2017-01-12T09:49:05Z
dc.date.available2017-01-12T09:49:05Z
dc.date.issued2016-09
dc.description.abstractMedical Laboratories Accreditation is covered by ISO 15189:2012 - Medical Laboratories — Requirements for Quality and Competence. In Portugal, accreditation processes are held under the auspices of the Portuguese Accreditation Institute (IPAC), which applies the Portuguese edition (NP EN ISO 15189:2014). Accordingly, Medical Laboratories accreditation processes now require the estimate of measurement uncertainty (MU) associated to the results. The Guide to the Expression of Uncertainty in Measurement (GUM) describes the calculation of MU, not contemplating the specific aspects of medical laboratory testing. Several models have been advocated, yet without a final consensus. Given the lack of studies on MU in Portugal, especially on its application in the medical laboratory, it is the objective of this thesis to reach to a model that fulfils the IPAC’s accreditation regulations, in regards to this specific requirement. The study was based on the implementation of two formulae (MU-A and MU-B), using the Quality Management System (QMS) data of an ISO 15189 Accredited Laboratory. Including the laboratory’s two Cobas® 6000–c501 (Roche®) analysers (C1 and C2) the work focused three analytes: creatinine, glucose and total cholesterol. The MU-B model formula, combining the standard uncertainties of the method’s imprecision, of the calibrator’s assigned value and from the pre-analytical variation, was considered the one best fitting to the laboratory's objectives and to the study's purposes, representing well the dispersion of values reasonably attributable to the measurand final result. Expanded Uncertainties were: Creatinine - C1 = 9,60%; C2 = 5,80%; Glucose - C1 = 8,32%; C2 = 8,34%; Cholesterol - C1 = 4,00%; C2 = 3,54 %. ...[cont.].en_UK
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/11258
dc.language.isoenen_UK
dc.publisherCranfield Universityen_UK
dc.rights© Cranfield University, 2016. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.en_UK
dc.subjectAccreditationen_UK
dc.subjectISO15189 Standarden_UK
dc.subjectTechnical Requirementen_UK
dc.subjectTop-Downen_UK
dc.subjectCalibration Hierarchyen_UK
dc.subjectTraceabilityen_UK
dc.subjectTruenessen_UK
dc.subjectBiasen_UK
dc.subjectIntermediate Precisionen_UK
dc.subjectImprecisionen_UK
dc.subjectPre-analytical Phaseen_UK
dc.subjectVariationen_UK
dc.titleEstimating measurement uncertainty in the medical laboratoryen_UK
dc.typeThesis or dissertationen_UK
dc.type.qualificationlevelDoctoralen_UK
dc.type.qualificationnamePhDen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Placido_R_2016.pdf
Size:
4.45 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission
Description: