Development of leak-before-break filament wound composite structures.

dc.contributor.advisorSkordos, Alexandros A.
dc.contributor.advisorKazilas, Mihalis C.
dc.contributor.advisorYazdani Nezhad, Hamed
dc.contributor.authorLoukodimou, Vasiliki
dc.date.accessioned2023-10-31T16:31:12Z
dc.date.available2023-10-31T16:31:12Z
dc.date.issued2019-11
dc.description.abstractA leak-before-break (LBB) concept was developed for composite pressure vessels (CPVs) to achieve a safe, predictable and controllable way of failure preventing the consequences of a catastrophic rupture. Artificial defects were introduced in the structure in prearranged patterns, acting as weak areas and enforcing failure initiation and propagation from these locations. A continuum damage constitutive model was developed through testing and simulation of tensile and compression specimens at [0°]8, specimens under cyclic in-plane shear at [±45°]2s, [+45°]₈ and [±67.5°]₂s as well as out-of-plane specimens at [0°]₁₀ and [0°]₁₂. A methodology was established for the introduction of artificial defects in the composite material for its failure control considering fibre cuts and interfacial defects. The LBB concept was investigated through the simulation of the behaviour of CPVs including defects under internal pressurisation. The assessment of the LBB behaviour was based on the ability to discern between the occurrence of two leakages; the first associated to the leakage phenomenon for pressure relief in the case of over-pressurisation and the second corresponding to ultimate failure. The influence of size and degree of damage induced through the defects was investigated, as well as the use of local reinforcing patches to enhance the LBB behaviour. The most suitable design for the optimal function of the LBB behaviour involves a circular fibre cut defective area of 87.5% fibre cut damage which results in a clear separation between leak and damage by a pressure difference of about 280 bar. The selected case was used for the manufacturing of a closed-end loaded composite pipe to validate the concept. The results of the testing showed that leakage did not occur from the introduced weak points due to manufacturing defects; however, the prediction of the damage initiation from the introduced defects was accurately identified with a difference of 2% compared to the simulation results.en_UK
dc.description.coursenamePhD in Manufacturingen_UK
dc.identifier.urihttps://dspace.lib.cranfield.ac.uk/handle/1826/20481
dc.language.isoenen_UK
dc.publisherCranfield Universityen_UK
dc.publisher.departmentSATMen_UK
dc.rights© Cranfield University, 2019. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.en_UK
dc.subjectComposite pressure vesselsen_UK
dc.subjectinternal pressurisationen_UK
dc.subjectartificial defectsen_UK
dc.subjectleak-before-breaken_UK
dc.subjectdamage modelen_UK
dc.subjectcontinuum damage constitutive modelen_UK
dc.titleDevelopment of leak-before-break filament wound composite structures.en_UK
dc.typeThesis or dissertationen_UK
dc.type.qualificationlevelDoctoralen_UK
dc.type.qualificationnamePhDen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Loukodimou_V_2019.pdf
Size:
9.03 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: