X-ray backscatter radiography with lower open fraction coded masks

dc.contributor.authorMunoz, Andre Arelius Marcus
dc.contributor.authorVella, Anna
dc.contributor.authorHealy, M. J. F.
dc.contributor.authorLane, David W.
dc.contributor.authorJupp, Ian
dc.contributor.authorLockley, D.
dc.date.accessioned2017-10-18T11:05:26Z
dc.date.available2017-10-18T11:05:26Z
dc.date.issued2017-08-10
dc.descriptionCopyright 2017 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.en_UK
dc.description.abstractSingle sided radiographic imaging would find great utility for medical, aerospace and security applications. While coded apertures can be used to form such an image from backscattered X-rays they suffer from near field limitations that introduce noise. Several theoretical studies have indicated that for an extended source the images signal to noise ratio may be optimised by using a low open fraction (<0.5) mask. However, few experimental results have been published for such low open fraction patterns and details of their formulation are often unavailable or are ambiguous. In this paper we address this process for two types of low open fraction mask, the dilute URA and the Singer set array. For the dilute URA the procedure for producing multiple 2D array patterns from given 1D binary sequences (Barker codes) is explained. Their point spread functions are calculated and their imaging properties are critically reviewed. These results are then compared to those from the Singer set and experimental exposures are presented for both type of pattern; their prospects for near field imaging are discussed.en_UK
dc.identifier.citationMunoz AAM, Vella A, Healy MJF, Lane DW, Jupp I, Lockley D (2017). X-ray backscatter radiography with lower open fraction coded masks; Proceedings of SPIE 10393; Radiation Detectors in Medicine, Industry, and National Security XVIII 103930A (DOI: 10.1117/12.2273784)en_UK
dc.identifier.issn0277-786X
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/12656
dc.publisherSPIEen_UK
dc.titleX-ray backscatter radiography with lower open fraction coded masksen_UK
dc.typeConference paperen_UK

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
X-Ray backscatter radiography.pdf
Size:
403.79 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission
Description: