dc.description.abstractA molecularly imprinted polymer (MIP) film for domoic acid (DA) was synthesised by direct photo-grafting onto a gold chip suitable for a surface plasmon resonance (SPR) based bioanalytical instrument system, the BIAcore 3000™. The gold surface was first functionalised with a self-assembled monolayer of 2- mercaptoethylamine and subsequent carbodiimide chemistry was performed for covalent attachment of the photoinitiator, 4,4′-azobis(cyanovaleric acid). This ensured that the formation of the MIP thin film, comprising 2-(diethylamino) ethyl methacrylate as functional monomer and ethylene glycol dimethacrylate as cross-linker, occurred only at the surface level. Optimisation and control over the grafting procedure were achieved using contact angle measurements and atomic force microscope (AFM) imaging. The surface grafting resulted in the formation of thin and homogeneous MIP film with thickness of 40 nm. A competitive binding assay was performed with free DA and its conjugate with horseradish peroxidase, which was used as a refractive label. The sensor was evaluated for its sensitivity, cross-reactivity, and robustness by using a BIAcore 3000™. Likewise, monoclonal antibodies acting as natural receptors for the toxin were studied with the same BIAcore system. Results of a comparison between the artificial and natural receptors are reported. In contrast to monoclonal antibodies, the regeneration of MIP chip did not affect its recognition properties and continuous measurement was possible over a period of at least 2 men_UK
dc.identifier.citationM. Lotierzo, O. Y. F. Henry, S. Piletsky, I. Tothill, D. Cullen, M. Kania, B. Hock, A. P. F. Turner, Surface plasmon resonance sensor for domoic acid based on grafted imprinted polymer, Biosensors and Bioelectronics, Volume 20, Issue 2, Special Issue in Honour of Professor Pierre Coulet, 15 September 2004, Pages 145-152-
dc.identifier.issn0956-5663-
dc.identifier.urihttp://dx.doi.org/10.1016/j.bios.2004.01.032-
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/3439
dc.language.isoen_UK-
dc.publisherElsevier Science B.V., Amsterdam.en_UK
dc.subjectDomoic aciden_UK
dc.subjectMIPen_UK
dc.subjectThin filmsen_UK
dc.subjectSPRen_UK
dc.subjectAFMen_UK
dc.titleSurface plasmon resonance sensor for domoic acid based on grafted imprinted polymeren_UK
dc.typeArticle-

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
surface plasmon resonance sensor-2004.pdf
Size:
77.38 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
18 B
Format:
Plain Text
Description: