Citation:
S. Marson, U.M. Attia, G. Lucchetta, A. Wilson, J.R. Alcock and D M Allen, Flatness optimization of micro-injection moulded parts: The case of a PMMA microfluidic component, Journal of Micromechanics and Microengineering, Volume 21, Number 11, 2011, Paper Number 115024.
Abstract:
Micro-injection moulding (µ-IM) has attracted a lot of interest because of its potential for the production of low-cost, miniaturized parts in high-volume. Applications of this technology are, amongst others, microfluidic components for lab-on-a-chip devices and micro-optical components. In both cases, the control of the part flatness is a key aspect to maintaining the component's functionality. The objective of this work is to determine the factors affecting the flatness of a polymer part manufactured by µ-IM and to control the manufacturing process with the aim of minimizing the in-process part deformation. As a case study, a PMMA microfluidic substrate with overall dimensions of 10 mm diameter and 1 mm thickness was investigated by designing a µ-IM experiment having flatness as the experimental response. The part flatness was measured using a micro-coordinate measuring machine. Finite elements analysis was also carried out to study the optimal ejection pin configuration. The results of this work show that the control of the µ-IM process conditions can improve the flatness of the polymer part up to about 15 µm. Part flatness as low as 4 µm can be achieved by modifying the design of the ejection system according to suggested guidelines