Experimental study on severe slugging mitigation by applying wavy pipes  

Show simple item record

dc.contributor.author Xing, Lanchang -
dc.contributor.author Yeung, Hoi -
dc.contributor.author Shen, Joseph -
dc.contributor.author Cao, Yi -
dc.date.accessioned 2013-02-05T23:08:22Z
dc.date.available 2013-02-05T23:08:22Z
dc.date.issued 2013-01-31T00:00:00Z -
dc.identifier.citation Lanchang Xing, Hoi Yeung, Joseph Shen, Yi Cao, Experimental study on severe slugging mitigation by applying wavy pipes, Chemical Engineering Research and Design, Volume 91, Issue 1, January 2013, Pages 18–28.
dc.identifier.issn 0263-8762 -
dc.identifier.uri http://dx.doi.org/10.1016/j.cherd.2012.06.020 -
dc.identifier.uri http://dspace.lib.cranfield.ac.uk/handle/1826/7820
dc.description.abstract Wavy pipes were installed in the pipeline for mitigating severe slugging in pipeline/riser systems. Experimental results have revealed that: with a wavy pipe applied, the operating region of severe slugging is reduced; the severity of severe slugging and oscillation flow is mitigated; the wavy pipe performs better with its outlet located upstream of the riser base. The wavy pipe is essentially reducing the slug length. For severe slugging the wavy pipe works by accelerating the movement of the gas in the pipeline to the riser base; for the oscillation flow it works by mixing the gas/liquid two phases. en_UK
dc.publisher Elsevier Science B.V., Amsterdam en_UK
dc.rights NOTICE: this is the author’s version of a work that was accepted for publication in Chemical Engineering Research and Design. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Chemical Engineering Research and Design, VOL 91, ISSUE 1, (2013) DOI: 10.1016/j.cherd.2012.06.020,
dc.title Experimental study on severe slugging mitigation by applying wavy pipes   en_UK
dc.type Article -


Files in this item

This item appears in the following Collection(s)

Show simple item record