Development of a disposable pyruvate biosensor to determine pungency in onions (Allium cepa L.)

Date published

2006-05-15

Free to read from

Supervisor/s

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Department

Type

Postprint

ISSN

0956-5663

Format

Citation

L.A. Abayomi, L.A. Terry, S.F. White and P.J. Warner, Development of a disposable pyruvate biosensor to determine pungency in onions (Allium cepa L.), Biosensors and Bioelectronics, Volume 21, Issue 11, 15 May 2006, Pages 2176-2179.

Abstract

A disposable prototype pyruvate biosensor was constructed using pyruvate oxidase immobilised on mediated meldolas blue electrodes to determine pungency in onions (Allium cepa L.). The optimum operating potential was +150 mV (versus Ag/AgCl). A strong correlation between the biosensor response and untreated onion juice of known pyruvate concentration 2–12 μmol/g fresh weight (FW) was demonstrated. The biosensor was able to differentiate between low and high pungency onions. The detection limit using 1 unit of pyruvate oxidase was 1–2 μmol/g FW. Optimum concentrations of co-factors TPP, FAD and MgSO4 comprising the enzyme cocktail were determined as being 0.04, 0.1 and 30 mM, respectively.

Description

Software Description

Software Language

Github

Keywords

Meldolas blue, Fresh produce, Quality assurance, Sweet onions

DOI

Rights

Relationships

Relationships

Supplements

Funder/s