Thermodynamics analysis of a novel absorption heat transformer-driven combined refrigeration and desalination system

Show simple item record

dc.contributor.author Beniwal, Ravi
dc.contributor.author Garg, Kapil
dc.contributor.author Tyagi, Himanshu
dc.date.accessioned 2023-02-17T13:29:36Z
dc.date.available 2023-02-17T13:29:36Z
dc.date.issued 2022-12-21
dc.identifier.citation Beniwal R, Garg K, Tyagi H. (2023) Thermodynamics analysis of a novel absorption heat transformer-driven combined refrigeration and desalination system, Energy Conversion and Management, Volume 277, February 2023, Article number 116597 en_UK
dc.identifier.issn 0196-8904
dc.identifier.uri https://doi.org/10.1016/j.enconman.2022.116597
dc.identifier.uri https://dspace.lib.cranfield.ac.uk/handle/1826/19211
dc.description.abstract Preservation of food and medicines below sub-zero temperatures is the need of the present times. To achieve the required temperature using renewable energy, a waste heat-driven vapour absorption refrigeration system can be implemented. Majority of the available waste heat is available in the low temperature range i.e. between 60–80 °C, which cannot be directly used to provide refrigeration. Therefore, an absorption heat transformer (AHT) is coupled with the VARS (Vapour absorption refrigeration system) system which increases temperature of this waste heat, and the upgraded heat is utilized to produce required refrigeration effect. Further, the rectifiers’ waste heat of the absorption system will be used to power humidification-dehumidification (HDH) desalination cycle. Although all these three components (AHT, VARS, and HDH) have been studied individually, but they have never been combined altogether. This paper presents a mathematical model for the proposed system and its validation against published available literature. The performance parameters such as coefficient of performance, gain output ratio and refrigeration effect of the system is evaluated at different evaporator and desorber temperatures. For 300 kW waste heat at 80 °C, evaporator (VARS) temperature of −10 °C, the system reported 70 kW of refrigeration effect is provided with 20 kg/hr of distillate production rate. An exergy destruction of 82.64 kW has been reported for total input exergy of 142.2 kW, for refrigeration capacity of 157 kW. en_UK
dc.language.iso en en_UK
dc.publisher Elsevier en_UK
dc.rights Attribution-NonCommercial-NoDerivatives 4.0 International *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/ *
dc.subject Vapour absorption refrigeration en_UK
dc.subject Humidification-dehumidification en_UK
dc.subject Desalination en_UK
dc.subject Waste heat en_UK
dc.subject Gain output ratio en_UK
dc.subject Upgraded heat en_UK
dc.title Thermodynamics analysis of a novel absorption heat transformer-driven combined refrigeration and desalination system en_UK