Heat dissipation from a stationary brake disc, Part 1: Analytical modelling and experimental investigations

Show simple item record

dc.contributor.author Stevens, Kevin
dc.contributor.author Tirovic, Marko
dc.date.accessioned 2017-06-13T13:21:46Z
dc.date.available 2017-06-13T13:21:46Z
dc.date.issued 2017-05-18
dc.identifier.citation Kevin Stevens and Marko Tirovic. Heat dissipation from a stationary brake disc, Part 1: Analytical modelling and experimental investigations. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, Vol. 232, Issue 9, 2018, pp. 1707-1733 en_UK
dc.identifier.issn 0954-4062
dc.identifier.uri http://dx.doi.org/10.1177/0954406217707983
dc.identifier.uri https://dspace.lib.cranfield.ac.uk/handle/1826/12011
dc.description.abstract The main aim of the research is to support the development of the commercial vehicle electric parking brake. Though nowadays widely used on passenger cars, electric parking brake applications on commercial vehicles present completely different challenges. With the brake mass, thermal capacity and required clamp forces an order of magnitude higher, safe parking demands much more attention. In the first instance, the priority is placed upon predicting heat dissipation from the brake disc only. The research is presented in two parts; part one (presented here) focuses on analytical modelling and experimental verification of predicted disc temperatures over long cooling periods, with part two investigating the air flow, velocities and convective heat transfer coefficients using computational fluid dynamics modelling, also followed by experimental validations. To begin the analytical analysis, a study was conducted into the variance in mean local convective heat transfer coefficients over a simplified brake disc friction surface, by investigating typical dimensionless air properties. A nonlinear equation was derived for the average surface convective heat transfer coefficient (h conv hconv ) variability with temperature drop for the entire cooling phase. Starting from fundamental principles, first-order differential equations were developed to predict the bulk disc temperature. By including variation of the convective and radiative heat dissipation throughout the cooling period, a good correlation was achieved with measured values, to within 10%. Experiments were conducted on a specifically designed thermal rig which uses 15 kW induction heater to heat the disc. Numerous experiments proved the results are very repeatable, throughout the cooling period. It was established, for the grey cast iron brake disc with a fully oxidised surface, the emissivity value are practically constant at ɛ = 0.92. Although the research is being conducted on a brake disc, the results have generic application to any disc geometry, whatever the application. en_UK
dc.language.iso en en_UK
dc.publisher SAGE en_UK
dc.rights Attribution-NonCommercial 4.0 International
dc.rights.uri http://creativecommons.org/licenses/by-nc/4.0/
dc.subject Stationary disc en_UK
dc.subject brake disc en_UK
dc.subject convective cooling en_UK
dc.subject emissivity en_UK
dc.subject heat dissipation en_UK
dc.title Heat dissipation from a stationary brake disc, Part 1: Analytical modelling and experimental investigations en_UK
dc.type Article en_UK
dc.identifier.cris 17723126


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial 4.0 International Except where otherwise noted, this item's license is described as Attribution-NonCommercial 4.0 International

Search CERES


Browse

My Account

Statistics