Effects of μCT and FE resolution in expressing anisotropic properties in vertebral cancellous bone

Show simple item record

dc.contributor.author Shanker, Tobias
dc.contributor.author Franceskides, Constantinos
dc.contributor.author Gibson, Michael C.
dc.contributor.author Clasper, J.
dc.contributor.author Adams, George
dc.contributor.author Zioupos, Peter
dc.date.accessioned 2017-02-01T15:52:00Z
dc.date.available 2017-02-01T15:52:00Z
dc.date.issued 2016-09-15
dc.identifier.citation Shanker T, Franceskides C, Gibson M, Clasper J, Adams G, Zioupos P (2016) Effects of μCT and FE resolution in expressing anisotropic properties in vertebral cancellous bone. In 51st UK Conference on Human Responses to Vibration; Gosport, 14-15/09/2016. (eds) Paddan, G S ISBN: 9780954602840 en_UK
dc.identifier.uri http://dspace.lib.cranfield.ac.uk/handle/1826/11383
dc.identifier.uri https://www.royalnavy.mod.uk/hrv2016
dc.description.abstract With an aging population lower back pain is a growing concern amongst many people. Recent developments in FE have made possible the simulation of complex geometries, such as trabecular bone. Most current techniques homogenise vertebrae into solids with averaged material properties. This is undesirable as analysis on the effects within trabecular tissue is impossible. As vertebral tissue is highly anisotropic this study investigates the effects on anisotropy when the mesh resolution and orientation are varied. Trabecular cubes were taken from a human donor at different orientations around the medial-lateral axis (0°, 45°, 90°) and tested in all three axes. Prior to testing they were CT scanned (X-Tek), reconstructed (CTPro) for and meshed (ScanlP). The full size scans were linearly downsampled to 32pm, 50pm, 64pm, 128pm and 256pm. Using a power-law based on material properties in the literature (E=15GPa, p=1800 g/cm3 and v=0.3) each mesh was quasi-statically compressed in all three directions. Our finite-element analysis shows good agreement with the experimental results, showing that a pixel resolution of 64pm is good for preserving anisotropy in vertebral bone. This model was further validated against the other models at different orientations also showing a good agreement with the experimental results.
dc.publisher Institute of Naval Medicine en_UK
dc.rights Attribution-NonCommercial 4.0 International
dc.rights.uri http://creativecommons.org/licenses/by-nc/4.0/
dc.title Effects of μCT and FE resolution in expressing anisotropic properties in vertebral cancellous bone en_UK
dc.type Conference paper en_UK


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial 4.0 International Except where otherwise noted, this item's license is described as Attribution-NonCommercial 4.0 International

Search CERES


Browse

My Account

Statistics