Test report no. PLBO/15 intermittent cutting tests with tools of RD107, RD110 and SIP, having radiused cutting edges

Show simple item record

dc.contributor.author College of Aeronautics, (Cranfield)
dc.date.accessioned 2016-10-21T11:26:33Z
dc.date.available 2016-10-21T11:26:33Z
dc.date.issued 1965-01
dc.identifier.uri http://dspace.lib.cranfield.ac.uk/handle/1826/10824
dc.description.abstract Tools of grade S1P„ RD1O7 and RD11O with radiused cutting edges were tested to failure cutting slotted bars of EN9 at 600 f.p.m., 0.010 in/rev. feed and 0.10 in depth of cut. The results showed that there was a reduction in the frequency of early tool failure as compared with unradiused tips. A statistical analysis showed that there was no significant difference between the mean tool lives of the three grades. en_UK
dc.language.iso en en_UK
dc.publisher College of Aeronautics en_UK
dc.relation.ispartofseries CoA/M/M&P-57 en_UK
dc.relation.ispartofseries 57 en_UK
dc.title Test report no. PLBO/15 intermittent cutting tests with tools of RD107, RD110 and SIP, having radiused cutting edges en_UK
dc.type Report en_UK


Files in this item