Test report no. PLBO/6: wear tests of PERPRO tools grade CLV, machining meehanite

Show simple item record

dc.contributor.author College of Aeronautics, (Cranfield)
dc.date.accessioned 2016-10-21T09:14:21Z
dc.date.available 2016-10-21T09:14:21Z
dc.date.issued 1963-12
dc.identifier.uri http://dspace.lib.cranfield.ac.uk/handle/1826/10814
dc.description.abstract Tools of grade CLV were tested at 300 fpm cutting speed, 0.010 in./rev. feed and 0.10 in. depth of cut to 0.030 in. flankwear. The results gave a mean tool life of 37 minutes which should be compared with the results given in Report No. PLB0/1 for grades CLV 403, A, B and C. en_UK
dc.language.iso en en_UK
dc.publisher College of Aeronautics en_UK
dc.relation.ispartofseries CoA/M/M&P-14 en_UK
dc.relation.ispartofseries 14 en_UK
dc.title Test report no. PLBO/6: wear tests of PERPRO tools grade CLV, machining meehanite en_UK
dc.type Report en_UK