Browsing by Author "Stevens, Kevin"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Open Access Heat dissipation from a stationary brake disc, Part 1: Analytical modelling and experimental investigations(SAGE, 2017-05-18) Stevens, Kevin; Tirovic, MarkoThe main aim of the research is to support the development of the commercial vehicle electric parking brake. Though nowadays widely used on passenger cars, electric parking brake applications on commercial vehicles present completely different challenges. With the brake mass, thermal capacity and required clamp forces an order of magnitude higher, safe parking demands much more attention. In the first instance, the priority is placed upon predicting heat dissipation from the brake disc only. The research is presented in two parts; part one (presented here) focuses on analytical modelling and experimental verification of predicted disc temperatures over long cooling periods, with part two investigating the air flow, velocities and convective heat transfer coefficients using computational fluid dynamics modelling, also followed by experimental validations. To begin the analytical analysis, a study was conducted into the variance in mean local convective heat transfer coefficients over a simplified brake disc friction surface, by investigating typical dimensionless air properties. A nonlinear equation was derived for the average surface convective heat transfer coefficient (h conv hconv ) variability with temperature drop for the entire cooling phase. Starting from fundamental principles, first-order differential equations were developed to predict the bulk disc temperature. By including variation of the convective and radiative heat dissipation throughout the cooling period, a good correlation was achieved with measured values, to within 10%. Experiments were conducted on a specifically designed thermal rig which uses 15 kW induction heater to heat the disc. Numerous experiments proved the results are very repeatable, throughout the cooling period. It was established, for the grey cast iron brake disc with a fully oxidised surface, the emissivity value are practically constant at ɛ = 0.92. Although the research is being conducted on a brake disc, the results have generic application to any disc geometry, whatever the application.Item Open Access Heat dissipation from a stationary brake disc, Part 2: CFD modelling and experimental validations(SAGE, 2017-05-18) Tirovic, Marko; Stevens, KevinFollowing from the analytical modelling presented in Part 1, this paper details a comprehensive computational fluid dynamics modelling of the three-dimensional flow field around, and heat dissipation from, a stationary brake disc. Four commonly used turbulence models were compared and the shear stress turbulence model was found to be most suitable for these studies. Inferior cooling of the anti-coning disc type is well known but the core cause in static conditions was only now established. The air flow exiting the lower vane channels at the inner rotor diameter changes direction and flows axially over the hat region. This axial flow acts as a blocker to the higher vane inlets, drastically reducing convective cooling from the upper half of the disc. The complexity of disc stationary cooling is further caused by the change of flow patterns during disc cooling. The above axial flow effects slowly vanish as the disc temperatures reduce. Consequently, convective heat transfer coefficients are affected by both, the change in the flow pattern and decrease in air velocities due to reduced air buoyancy as the disc cools down. As in Part 1, the special thermal rig was used to validate the computational fluid dynamics results quantitatively and qualitatively. The former used numerous thermocouples positioned strategically around the brake disc, with the latter introducing the concept of laser generated light plane combined with a smoke generator to enable flow visualisation. Predicted average heat transfer coefficients using computational fluid dynamics correlate well with the experimental values, and even two-dimensional analytical values (as presented in Part 1) reasonably closely follow the trends. The results present an important step in establishing cooling characteristics related to the electric parking brake application in commercial vehicles, with future publications detailing heat transfer from the entire brake assembly.Item Open Access An investigation into heat dissipation from a stationary commercial vehicle disc brake in parked conditions.(Cranfield University, 2013-11) Stevens, Kevin; Tirovic, Marko; Skipworth, HeatherDetailed understanding of heat dissipation from a stationary disc brake is of considerable importance for vehicle safety. This is essential for both park braking on inclines and for preventing brake fluid boiling in hydraulic brakes. Despite the experience proving the significance of such conditions, there is very little published data dealing with this phenomenon, and even ECE Regulation 13 does not specify hot parking braking performance. The problem of heat dissipation from stationary brake may appear simplistic but it is actually more complex than from a rotating disc, due to the lack of symmetry through or a dominant mode of heat transfer as natural convection is the only driving force behind the airflow. All three heat transfer modes exist in a transient process, with complex heat transfer paths within and between brake components. This Thesis investigates the cooling performance of a Commercial Vehicle (CV) brake whilst in stationary conditions. The research is predominantly orientated towards the thermal aspects of Electric Parking Brake (EPB) application in CVs. Contraction of large brake components after hot parking may lead to vehicle rollaway on inclines, with tragic consequences. An extensive theoretical and experimental study was conducted. An analytical model of a disc brake in free air was developed, enabling good prediction of disc temperatures and average surface convective heat transfer coefficients (hcₒnv) over the entire cooling range. A comprehensive CFD modelling of the 3-dimensional flowfield around the disc brake was also conducted, as well as predicting the surface convection coefficient distribution. Shear Stress Turbulence model was found to be most suitable for such studies. FE models were created to predict temperatures in all components of the brake assembly. A special Thermal Rig was developed for experimental validations, which uses an induction heater for heating the disc brake, and numerous surface mounted and embedded thermocouples for measuring component temperatures, as well as ‘free standing’ for determining air temperatures in specific points. IR cameras provided further temperature field information. The results clearly show little influence of the conductive heat dissipation mode. The study also showed, for the experimental arrangement used, a constant value of surface emissivity (ɛ = 0.92). With well-defined conductive and radiative heat dissipation modes, the emphasis was placed on investigating convective heat dissipation from a stationary disc brake. It has been demonstrated that the anti-coning straight vane design of brake disc does not cool effectively in stationary conditions. Expected ‘chimney effects’ in disc vent channels do not materialise due to large scale recirculation regions preventing airflow from entering the channels, which drastically reduces the convective cooling. Complex thermal interactions between the large assembly components are explained, with typical cooling time being just over an hour for disc brake cooling from 400°C to 100°C. Extracted heat transfer coefficients were used for establishing a complex FE assembly model, which enables accurate prediction of temperatures of individual components over the entire cooling period. The developed approach is used for predicting temperature of the existing brake assembly but is equally suited for generating new designs with more favourable characteristics. In addition to being a powerful design tool for assisting in EPB design and validation process, the methodology developed offers wide applications, such as thermal optimisation of the caliper housing for the installation of continuous wear monitoring sensors, smart slack adjusters (for low friction drag brakes), etc. EPBs in passenger cars have been successfully used for over 10 years now. They use a relatively simple approach for ensuring safe parking from hot by over-clamping (applying approximately twice the required actuating force) and re-clamping (repeated application after the vehicle has been parked). Large CV actuating forces prevent the use of over-clamping as this could damage the disc, whilst re-clamping would need to be repeated several times over a much longer period of time, requiring the vehicle battery to power the electronic systems for a longer period of time without recharging. Neither approach is acceptable, requiring a more in- depth thermal study of the CV brake in stationary conditions, as investigated in this Thesis. In addition to technical, there are marketing and financial aspects which make EPB introduction and acceptance in commercial vehicles very different to passenger car applications. Such an investigation was conducted, exploring the market the CV EPB will be sold in and whether it would accept the new technology. Two questionnaire analyses were carried out, with the second giving the respondent detailed information about the EPB. It was found that using an informed, knowledge based approach yielded more positive feedback to the proposed product. The outcome may be even considered more contrary than expected, rather than instigating mistrust, the new CV EPB technology created interest. Furthermore, reports of pneumatic malfunction indicated that independence from the pneumatic system should be used as the key selling point for the EPB, for all beneficiary segments.