Rig Labview Data: 1) Time (sec) - this is the time in seconds since start of each individual run 2) Air massflow (kg/s) - this is the air massflow from the compressor measured using an orifice plate and a differential pressure sensor in the lab 3) Water flow (lpm) - this is the setting for the water flowing through the system into the atomizer nozzles in litres/minute measured using a flowmeter prior to injection into the nozzle 4) Supply air pressure (bar) - this is the air pressure from the main compressor supply in bar read using the pressure sensors in supply pipe at outlet of compressor 5) Pipe upstream pressure (bar) - this is the pressure at the upstream location in the 5m pipe within the rig read using a pressure sensor in bar, after nozzle injection point 6) Pipe downstream pressure (bar)- this is the pressure at the downstream location in the 5m pipe within the rig read using a pressure sensor in bar, before turbine inlet 7) Pipe upstream temp (deg C)- this is the temperature at the upstream location in the 5m pipe within the rig read using a thermocouple in deg C, after nozzle injection point 8) Pipe downstream temp (deg C) - this is the temperature at the downstream location in the 5m pipe within the rig read using a thermocouple in deg C, before turbine inlet 9) Turbo exhaust temp (deg C) - this is the temperature at the turbine exhaust read using a protected/insulated thermocouple in deg C 10) Turbo oil temp (deg C) - this is the temperature of the oil flow on it's return path to the oil tank used in conjuction with the turbocharger in deg C 11) Supply air temp (deg C) - this is the temperature from the main compressor supply in deg C read using the thermocouples in supply pipe at outlet of compressor 12) Turbo RPM - this is the turbine rpm read using a turbine speed sensor and probe setup 13) Relative Humidity (%) - this is the relative humidity before the turbine inlet in RH% read using a Chilled Mirror inserted into the rig airflow 14) RH RTD temp (deg C) - this is the temperature read by the chilled mirror for the RH calculations