Roman-Ramirez, Luis A.; Leeke, Gary A.
(American Chemical Society, 2016-05-16)
Experimental – data were measured for the (acetic acid + water) system at the temperatures of (412.6, 443.2 and 483.2) K between the pressures of 196 kPa and 1902 kPa over the entire range of concentrations. Experiments ...