Part mass and shrinkage in micro injection moulding: statistical based optimisation using multiple quality criteria

Show simple item record

dc.contributor.author Annicchiarico, Daniele -
dc.contributor.author Attia, Usama M. -
dc.contributor.author Alcock, Jeffrey R. -
dc.date.accessioned 2014-01-24T05:04:48Z
dc.date.available 2014-01-24T05:04:48Z
dc.date.issued 2013-09-30T00:00:00Z -
dc.identifier.citation D. Annicchiarico, U.M. Attia, J.R. Alcock, Part mass and shrinkage in micro injection moulding: statistical based optimisation using multiple quality criteria, Polymer Testing, Volume 32, Issue 6, 2013, Pages 1079-1087.
dc.identifier.issn 0142-9418 -
dc.identifier.uri http://dx.doi.org/10.1016/j.polymertesting.2013.06.009 -
dc.identifier.uri http://dspace.lib.cranfield.ac.uk/handle/1826/8149
dc.description.abstract Purpose: The aim of this paper is to optimise process conditions in micro injection moulding (m-IM) to minimise shrinkage whilst maximising part mass. Method: A Design of Experiment (DoE) approach was implemented for studying the effect of five processing parameters on shrinkage and part mass. A multiple quality criteria based analysis was used to optimise the process. Results: Significant factors were found for shrinkage and part mass. Conclusions: The multi quality criteria could be optimized, and this optimization validated experimentally. en_UK
dc.language.iso en_UK -
dc.publisher Elsevier Science B.V., Amsterdam. en_UK
dc.rights NOTICE: this is the author’s version of a work that was accepted for publication in Polymer Testing. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Polymer Testing, VOL 32, ISSUE 6, (2013) DOI: 10.1016/j.polymertesting.2013.06.009
dc.subject Part mass Shrinkage Micro injection moulding Optimization Multiple quality criteria en_UK
dc.title Part mass and shrinkage in micro injection moulding: statistical based optimisation using multiple quality criteria en_UK
dc.type Article -